Email:qiaosun-001@163.com
All Categories
Standard

Inorganic liquid detection Medical detection Animal residue detection Environmental detection Pesticide residue detection Food detection Matrix detection Engineering Technology detection Steel detection Metal Material detection Detection of polymer materials Physical detection Chemical detection Geological detection Imported reference materials

>

Thermo Scientific 5028i 连续颗粒物监测仪

产地:
Sale Price
Market Price Inquiry
  • Number
    减少数量 增加数量
Self-employed
Shop:
Cloud Fine chemicals
E-mail:
qiaosun-100@163.com
Call:
4006226992
Address:
No.6, New Garden 1st Road, Bishui Tianyuan Avenue, Dalang Town, Dongguan City, Guangdong Province

Mobile Mall

Recommended Products

Related Brands

New Product

  • Name:Thermo Scientific 5028i 连续颗粒物监测仪
  • ID:SBYQ77
  • Brand:Thermo Fisher
  • Uploaded:2018-07-24
流量稳定性:
 稳定
最低检出限(µg/m3):
 <1ug/m3(24小时)
采样流量:
 1m3/h
测量周期:
 连续监测
测量量程:
 0-10mg/m3或0-10000ug/m3
价格区间:
 25万-40万
测量方法:
 β射线法
测定参数:
 双参数PM2.5/ PM10

The Thermo ScientificTM Model 5028i连续颗粒物监测仪采用β射线衰减测量技术,并结合成熟的i系列平台而设计开发的全新颗粒物监测仪器。

主要特点

·        美国环保署认证的PM10EQPM1102-150)和PM2.5EQPM0609-183)联邦等效方法

·         双通道,真正连续,非步进式地同时测量PM10PM2.5

·        内部可充电电池,以缩短仪器断电恢复后的稳定时间

·         加长的滤纸带可实现更长时间的无人值守操作

·         设计上更加易于操作和维护


与其他的连续颗粒物监测仪不同,Model 5028i连续颗粒物监测仪配有两个独立的采样通道,可配备不同的采样头和切割器,实现PM10PM2.5的同时采样。PM10PM2.5被分别采集到两卷不同的滤纸带上,并由仪器内部两套相互独立的监测系统来同时测量。颗粒物质量测量和采样体积的测量结果被用于颗粒物质量浓度的计算。通过多种用户可选择的数据存储记录选项,颗粒物的质量浓度可以以实际工况浓度或标准状况浓度的形式输出。


Model 5028i可根据用户设定的条件来自动更新采集样品的滤纸带,用户可设定的条件参数包括采样的样品总量限值,采样时间间隔,或与流量相关的压力变量。


与步进式的测量方法相比,Model 5028i的滤纸带移动是单方向的,能有效减少颗粒物的损失。另外,加长的滤纸带可降低更换频率,支持更长时间的无人职守操作。

为了更准确地应对水分与挥发性组分损失造成的测量偏差,Model 5028i配备了动态加热系统,用户通过设置,能有效地控制样品的温度或湿度。


Specifications

规格

Source

放射源

-14, <3.7 MBq (<100 μCi)

Measurement Range

测量范围

0~0.1, 1.0, 2.0, 3.0, 5.0, 10.0 mg/m3;   0~100, 1000, 2000, 3000, 5000, 10000 μg/m3

Minimum Detection Limit

最低检出限

< 4 μg/m3 (1小时)@2σ; < 1 μg/m3 (24小时)@2σ

Resolution

分辨率

0.1 μg/m3

Precision

精度

± 3.0 μg/m3 < 80 μg/m3;   4-5 μg/m3 > 80 μg/m3 (24小时)

RMS Precision

RMS精度

PM2.5 < 5%, PM10   < 5% (24小时)

Accuracy (for mass measurement)

准确度 (对于质量测量)

± 5%, 使用NIST可溯源标准膜片

Air Flow Rate

采样流量

1 m3/h (16.67 L/min)

Sample Flow Precision

采样流量精度

测量值的± 2%

Sample Flow Accuracy

采样流量准确度

小于测量值的5%

Mass Concentration

质量浓度

60~3,600秒和24小时

Data Output Rate

数据输出频率

1

Operating Temperature

工作温度

环境温度可能在-30~50℃之间变化, 5028i的工作温度需在4~50℃之间, 且须不受外界气候影响

可选户外选件, 保护其不受外界气候的影响

Non-condensing

非冷凝

仪器内部小于95% RH

Output

输出

可选电压, RS232/RS485, TCP/IP, 10个继电器输出和断电指示   (标准). 0-204-20mA隔离电流输出 (选配)

Input

输入

16位数字输入   (标准), 80~10 VDC模拟输入 (选配)

Power Requirements

电源要求

110~120 VAC, 220~240 VAC, 50/60 Hz, 最大功率700 Watts

Pump

220 VAC 50/60 Hz, 2.0 A

Physical Dimensions

外观尺寸

18.96” (48.2 cm)宽×22.23” (56.5 cm)深×23.43” (59.5   cm)

Weight

重量

110 VAC: 77 lbs (35 kg); 220 VAC: 66 lbs (30   kg)

Protocols

通讯协议

C-Link, MODBUS, Gesytec (Bayern-Hessen), ESM协议, 数据流和NTP协议 (Network Time Protocol), 通过以太网可从不同地方同时连接

Safety and Electrical Designations

安全与电路设计

设计达到要求CE: EN 61326:1997 + A1:1998 + A2:2001 + A3:2003,   EN:61010-1; UL: 61010-1:2004; CSA: C22.2 No. 61010-1:2004; FCC: Part 15   Subpart B, Class B

Approvals and Certifications

认证

美国环保署PM10联邦等效方法认证:   EQPM1102-150

美国环保署PM2.5联邦等效方法认证:   EQPM0609-183









温馨提示

确定取消
温馨提示

关闭
用户登录×